Interrogating the Effects of Cold Joints on Strength and Durability of Concrete Structures

Authors

  • Tafadzwa Nyereyemhuka Author
  • Tinashe Nyamudeza Author

Keywords:

cold joints, compressive strength, durability, delay time, sorptivity

Abstract

Maintaining high structural integrity in large concrete structures which consume huge quantities of
concrete is often a difficult task due to the presence of cold joints. Cold joints occur when there are long
delays between pouring consecutive batches or layers of concrete. High structural integrity hinges on
the careful application of cold joints in the concrete structure and, for this reason, the performance
of cold joints needs to be carefully investigated. This study examined the impact of cold joints on
concrete strength and durability. The effect of delay time on compressive strength was investigated
using delays of six hours and 24 hours for vertical, horizontal and diagonal joints. The effect of the
number of cold joints on a structural element was also examined using three pours per test cube in
all three geometric orientations, with unjointed concrete cubes used as the control. The sorptivity test
was used to evaluate the susceptibility of the joints to capillary action. The greatest loss in strength
was found in concrete with 24-hour delay cold joints, with diagonal joints exhibiting the highest loss.
Diagonal joints had an average strength loss of 42%, followed by 25% for vertical joints, and 3% for
horizontal joints. The diagonal joint at six-hour delay time showed unexpected high strength which
has been theorised to be due to a higher surface area on the joint. Cold-jointed concrete showed
elevated water absorption during the initial stages but, overall, the difference in sorptivity between
cold-jointed and unjointed concrete was minimal. This study concluded that managing delay times
and joint types is critical for minimising strength losses in large-scale concrete projects such as dams
and buildings. While sorptivity may not pose a significant threat to cold-jointed structures not intended
for liquid containment, proper construction techniques remain essential to maintaining durability and
long-term performance.